harley oxygen sensor wiring

You search Auto repair manual PDF harley oxygen sensor wiring, if there are search results will appear below. If search results do not exist, please search by others keyword.



  harley oxygen sensor wiring Direct Download speed 5282 Kb/s

  harley oxygen sensor wiring Full Version speed 6162 Kb/s



SUZUKI SV 1000 RADIATOR (COOLING SYSTEM) SERVICE MANUAL

0

Filed Under (Suzuki) by admin on 26-02-2011

download
FI SYSTEM MALFUNCTION CODE AND DEFECTIVE CONDITION MALFUNCTION CODE DETECTED ITEM DETECTED FAILURE CONDITION CHECK FOR COO NO FAULT C11 Camshaft position sen- sor The signal does not reach ECM for more than 3 sec . after receiving the starter signal . The camshaft position sensor wiring and mechanical parts (Camshaft position sensor, intake cam pin, wiring/coupler con- nection) C12 Crankshaft position sensor The signal does not reach ECM for more than 2 sec . after receiving the starter signal . The crankshaft position sensor wiring and mechanical parts (Crankshaft position sensor, wiring/coupler connection) C13 Intake air pressure sensor The sensor should produce following voltage . (0.50 V < sensor voltage < 4 .85 V) Without the above range, C13 is indicated. Intake air pressure sensor, wiring/coupler connection C14 Throttle position sen- sor The sensor should produce following voltage . (0.20 V < sensor voltage < 4 .80 V) Without the above range, C14 is indicated. Throttle position sensor, wiring/coupler connection C15 Engine coolant temperature sensor The sensor voltage should be the following. (0.15 V <_ sensor voltage < 4 .5 V) Without the above range, C15 is indicated. Engine coolant temperature sensor, wiring/coupler connection C21 Intake air temperature sensor The sensor voltage should be the following. (0.15 V < sensor voltage < 4 .5 V) Without the above range, C21 is indicated. Intake air temperature sensor, wiring/coupler connection C22 Atmospheric pressure sensor The sensor voltage should be the following. (0.50 V < sensor voltage < 4 .5 V) Without the above range, C22 is indicated. Atm. pressure sensor, wiring/coupler connection C23 Tip over sensor The sensor voltage should be the following for more than 2 sec . after ignition switch turns ON . (0 .20 V < sensor voltage < 4 .80 V) Without the above value, C23 is indicated. Tip over sensor, wiring/coupler connection C24 or C25 Ignition signalCrankshaft position sensor signal is produced and ECM determines the ignition signal but signal from ignition coil is interrupted continuous by 4 times or more. In this case, the code C24 or C25 is indicated. Ignition coil, wiring/coupler connection, power supply from the battery SERVICING INFORMATION 8 .3 C28 Secondary throttle valve actuator No operating voltage is supplied from the ECM, C28 is indicated. STVA can not operate. STVA lead wire/coupler, STVA C29 Secondary throttle valve position sensor The sensor should produce following voltage . (0.10 V < sensor voltage < 4 .90 V) Without the above range, C29 is indicated . Secondary throttle position sensor, wiring/coupler connection C31 Gear position signalGear position signal voltage should be higher than the following for more than 2 seconds. (Gear position switch voltage >_ 0 .6 V) Without the above value, C31 is indicated. Gear position sensor, wiring/coupler connection, gearshift cam, etc. C32 or C33 Fuel injector Crankshaft position sensor signal is produced and ECM determines the injection signal but fuel injection signal is interrupted continuous by 4 times or more. In this case, the code C32 or C33 is indicated. Injector, wiring/coupler connection, power supply to the injector C41 Fuel pump relay No voltage is applied to fuel pump although fuel pump relay is turned ON, or voltage is applied to fuel pump although fuel pump relay is turned OFF . Fuel pump relay, connecting lead, power source to fuel pump relay C42 Ignition switchIgnition switch signal is not input in the ECM . Ignition switch, lead wire/coupler C44 Heated oxygen sensor (HO2S) [For E-02, 19] During 02 feedback control, 02 sensor voltage is higher or lower than the specification . No signal is detected during engine operation or no electrical power is supplied from the battery . HO2S lead wire/coupler connection Battery voltage supply to the HO2S C49 PAIR control solenoid valve (PAIR valve) When no operating voltage is supplied from the ECM, C49 is indicated. PAIR valve can not operate. PAIR valve lead wire/coupler

WEGO II Wide-Band Exhaust Gas Oxygen Sensor Interface Installation Instructions

0

Filed Under (Tips and Review) by admin on 27-10-2010

download
1. Turn off the ignition switch before proceeding. 2. Select a convenient mounting location for the Bosch sensor. In general, the sensor should be mounted as close to the exhaust valve or exhaust manifold as practical. When choosing a mounting location, allow several inches clearance for the sensor wire harness. The wire harness must exit straight out from the sensor. Do not loop the harness back onto the sensor body. The sensor responds to oxygen pressure. Excessive backpressure will cause a reading error. For turbocharged applications, you must mount the sensor downstream of the turbo. 3. For temporary use during dyno tuning, you can mount the Bosch wide-band sensor in place of one of the original equipment rear oxygen sensors (after the catalytic converter). You can also use a sniffer in the tailpipe. For permanent mounting, an 18 x 1.5 mm weld nut must be welded onto the exhaust pipe. After welding, run an 18 x 1.5 mm tap through the threads. Failure to clean the threads may result in sensor damage. Note that most automotive muffler shops are familiar with oxygen sensor weld nut installation on custom pipes. Do not install the sensor until after the free air calibration procedure described in the following section. Always use an anti-seize lubricant such as Permatex 133A on the sensor threads. 4. Install the WEGO II unit. The WEGO II unit should be mounted where the LCD display will be visible during testing. You can secure the WEGO II unit with Velcro tape strips. 5. Connect the Bosch sensor to the 6 pin mating connector on the WEGO II wire harness. 6. Refer to Figure 1. Connect the black WEGO II wire to frame ground using the supplied ring terminal. Try to use an existing wire harness ground location. Do not extend the WEGO II ground wire or ground the WEGO II to the battery minus terminal or to the engine. 7. Connect the red WEGO II wire to switched +12 volt power. You can usually find switched +12V power at an accessory fuse on the fuse block. You can use the supplied fuse tap and 3/16″ female crimp terminal for this purpose

WEGO IV Wide-Band Exhaust Gas Oxygen Sensor System Installation Instructions

0

Filed Under (Harley Davidson) by admin on 21-04-2012

download
1. Turn off the ignition switch before proceeding. 2. Select a convenient mounting location for the Bosch sensor. In general, the sensor should be mounted as close to the exhaust valve or exhaust manifold as practical. When choosing a mounting location, allow several inches clearance for the sensor wire harness. The wire harness must exit straight out from the sensor. Do not loop the harness back onto the sensor body. The sensor responds to oxygen pressure. Excessive backpressure will cause a reading error. For turbocharged applications, you must mount the sensor downstream of the turbo. 3. For temporary use during dyno tuning, you can mount the Bosch wide-band sensor in place of one of the original equipment rear oxygen sensors (after the catalytic converter). You can also use a sniffer in the tailpipe. For permanent mounting, an 18 x 1.5 mm weld nut must be welded onto the exhaust pipe. After welding, run an 18 x 1.5 mm tap through the threads. Failure to clean the threads may result in sensor damage. Note that most automotive muffler shops are familiar with oxygen sensor weld nut installation on custom pipes. Do not install the sensor until after the free air calibration procedure described in the following section. Always use an anti-seize lubricant such as Permatex 133A on the sensor threads. 4. Install the WEGO IV unit where the display will be visible during testing. The unit is not sealed and must be mounted in a dry location away from sources of heat. We recommend underdash mounting or use in a dyno lab environment. The unit is not intended for underhood mounting. The unit can be secured by means of Velcro tape strips. Use nylon tie wraps to secure the wire harness near the unit. 5. Working with clamping terminal blocks . All connections to the WEGO IV terminal block must be clearly identified either by means of distinct wire colors (such as shown in Figure 1) or wire labels. If you use different wire colors, mark up Figure 1 for future reference. All connections can be made with 18-20 AWG wire. Wire should be stripped back

Harley-Davidson Softail, Touring, Dyna, Sportster and V-Rod, SELF LEARNING MODULE INSTALLATION MANUAL

0

Filed Under (Harley Davidson) by admin on 17-04-2012

download
STEP 1 – BATTERY CONNECTION Locate the battery and disconnect the negative battery cable. Mount the module in the open area in front of the battery with 2-tie straps or velcro straps, directing the harness from the module towards the 6 o’clock position. STEP 2 – THROTTLE POSITION SENSOR (TPS): Remove the air cleaner assembly and unplug the TPS sensor connector at the TPS sensor. The harness includes (2) TPS connectors which should be routed under the gas tank into the factory wire loom to the TPS sensor. The TPS sensor is located on the left side of the throttle body. Plug the (2) TPS connectors from the module in between the TPS sensor and to the factory TPS connector. STEP 3 – O2 SENSOR: Systems equipped with factory O2 sensors Rear: Unplug the Rear O2 sensor connector from the factory harness, which is located at the Rear exhaust pipe. Route the module’s harness which includes (2) O2 sensor connectors and connect one connector to the Rear O2 sensor and connect the other connector to the main factory O2 sensor connector. Front: Unplug the Front O2 sensor connector from the factory harness, which is located at the Front exhaust pipe. Route the module’s harness which includes (2) O2 sensor connectors, and connect one connector to the Front O2 sensor and connect the other connector to the main factory O2 sensor connector. Systems not equipped with factory O2 sensors NOTE: Many aftermarket exhaust systems are now equipped with plugged O2 sensor bungs which can be removed to accept an aftermarket O2 sensor. Typically these bungs already have a thread size of 18 mm x 1.5 mm. Exhaust systems not equipped with O2 sensor bungs need to have the supplied 18 mm x 1.5 mm thread size bung welded to the exhaust pipe in order to install an O2 sensor. The O2 sensor bung should be installed 3 to 6 inches away from the rear cylinder exhaust port and in front of the exhaust torque tube pipe area. The module prefers to receive information from the O2 sensor from an area that is NOT contaminated from atmospheric air. This air may enter through the tail pipe of an unrestricted or un-baffled exhaust pipe. The bung should not be installed in the “5 to 7 o’clock” area. If mounted in this area the O2 sensor can be damaged. The moisture from the gases exiting from the rear cylinder exhaust port will harm the ceramic shell element of the O2 sensor.

2004 or later Harley Davidson Speedometer Installation MANUAL

0

Filed Under (Harley Davidson) by admin on 25-03-2012

download
Speed Sensor Installation: The microSpeed™ speedometer can be used with either +12V or +5V hall effect electronic sensors located in transmission. Sensor is not include. If your sensor operates on +5V DC wire speedometer to sensor and power as shown in Figure 2 below. Please note that color of wires from the sensor may vary, check sensor documentation for proper signal connections. For +12V sensor you will not need the Blue wire of the microSpeed™ speedometer. It may be cut short, but make sure that the end is properly protected so that it will not accidentally short to metal on the motorcycle. Use Figure 3 below for wiring a +12V sensor. H-D motorcycles 1999 and earlier used +12V sensors. H-D motorcycles 2000 and later use +5V sensors. Note: H-D OEM sensors require 20Kohm resistor(provided) between Sensor power and Sensor signal as shown. Procedure: 1. Locate wires and determine connection points. Cut wires and techflex to proper lengths. 2. Connect speedometer wires to proper signal wires as shown in diagrams, including 20K ohm resistor if using stock H-D sensor. Use either butt connectors provided or customer supplied connectors. 3. Use electrical tape or Heat Shrink tubing around sensor signal wire, sensor power, and resistor to protect resistor. 4. Proceed to Setup Section below. Setup microSpeed™ Speedometer: 1. Before proceeding review User Guide document for detailed instructions on following procedure. 2. Turn on power to speedometer, display should read “odo” 3. Set initial odometer value 4. Turn off power for 2 seconds; then turn power on again 5. Display should read “F 0″ 6. Enter Configuration and Calibration and set speedometer to proper operating mode. a. Harley English b. Harley Metric c. Standard speed sensor English d. Standard speed sensor Metric 7. Set Fuel miles per tank 8. Set Oil change interval 9. Set Speed adjustment 10. Confirm. 11. Test speed is reporting properly and adjust is necessary